Common fault solutions for filling peristaltic pumps
2022-12-26
Filling peristaltic pump in the normal production and operation process encountered after the problem can be quickly eliminated to solve the problem, to avoid affecting the normal operation, will have important economic significance. According to the filling peristaltic pump in the daily use of some of the problems often encountered, giving a few common failures and the corresponding solutions.
In the filling of large specifications, the tank replenishment is not enough, resulting in unstable liquid level, you can increase the amount of replenishment or re-close the small filling head square ball valve, reset the filling time (longer filling time) to slow down the filling speed to solve.
Second, after adjusting the digital dial code or unit, the time does not change.
At this point, turn off the power to reconnect the power can be.
Third, the liquid level is stable, the filling volume is not accurate.
There are debris blocking the filling channel, mainly at the entrance of the trough or in the filling nozzle, check and clean it up.
Fourth, there is dripping after closing.
1、The orifice of the filling nozzle is damaged, you can take out the filling nozzle to fix the orifice.
2、The ball valve inside the filling head is damaged, need to replace the ball valve.
Five, after touching the material injection switch does not fill, time relay digital indication LED does not flash.
The injection switch is damaged or the time relay base is loose, replace the same type of injection switch or press the time relay base.
The Latest News
Purchase Channel
Service & Support
Solution
Products
Sign up for industry alerts, our latest news,thoughts, and insights from Axima You may withdraw your consent at any time!
Esperanto
Shqiptare
Euskara
Zulu
Latinus
Cymraeg
தமிழ்
Slovak
Slovak
Afrikaans
Copyright 2022 Changzhou Jiebeiyi Fluid Technology Co., Ltd Website construction: www.300.cn Changzhou 丨 seo